Set Stefan condition manually

Hello, I'm currently struggling with stefan problem and want to implement the stefan condition L(V.n)=Kl grad(T).n-Ks grad(T).n manually on the Solid/Liquid interface. L is latent heat, V is interface...

View Article



Re: Set Stefan condition manually

Hello, I have never met your problem and have not checked for a solution, but for (1), what about using 'Form Assembly' instead of 'Form Union' in order to break continuity at the interface...

View Article

Re: Set Stefan condition manually

Hello, I have never met your problem and have not checked for a solution, but for (1), what about using 'Form Assembly' instead of 'Form Union' in order to break continuity at the interface...

View Article

Re: Set Stefan condition manually

If I were you, I would try to add an 'heat flux' sub-node in the node 'continuity' to override the thermal insulation at the interface liquid/solid. There, you can specify q0 regarding to your needs....

View Article

Re: Set Stefan condition manually

If I were you, I would try to add an 'heat flux' sub-node in the node 'continuity' to override the thermal insulation at the interface liquid/solid. There, you can specify q0 regarding to your needs....

View Article